Data Logging Stick: S2-WL-ST. Support WiFi and LAN communication / Plug and play, quick installation . I haven't been able to log onto it after many attempts. RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. 1: Connect LAN stick to operational inverter to provide power to LAN stick. Communication quality may be affected in lightning storms. The decision to disable the feature was made via a poll last year. You should see a message that says "Bound Successfully" and now you will need to set up the logger on the localWiFinetwork. Data Logger into the port and be sure to secure it by tightening the black connector. This process can also be used to move a Solis Data Logger from one site to another. Step 5: Long press the Reset button for 5 seconds until the yellow and green LEDs are quickly flashing. Connect the antennae to the data logger; Plug the logger into the inverter - be sure the inverter is on with at least DC power; Open the Wi-Fi settings on your phone and then search for new networks . WiFi datalogger firmware is out of date. Apologies for the long story below. Sorry we couldn't be helpful. If you have aSolisCloudaccount already, then please follow the steps below to create a plant and commission a SolisWiFidata logger to the system. Technician check pins 1 and 2 for 5VDC, 3. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Solis datalogger installation instructions APP Enso Circle Space 2.1K subscribers Subscribe 84K views 3 years ago This instructional video shows you how to setup the WIFI monitoring on your. SolisCloud is the new generation of intelligent PV system monitoring. SolisCloud Step 2: If it is a new data logger, please configure it first, then click the " Willi configure". You will benefit from upgraded accurate fault alarm messaging that is adjustable to notify you within hours that fit meet your needs. This process can also be used to move a Solis Data Logger from one site to another. 2019-08-29 16:17:17. Solis WIFI and LAN Data Logger Datasheet.pdf, Solis WIFI Logger Installation Manual v2.4 (1).pdf. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. Solis-(75-100)K-5G-US Solis-125K-EHV-5G Solis-(185-255)K-EHV-5G-US RHI-1P(5-10)K-HVES-5G Data Logging Stick Data Logging Box Cellular Data Logger Case Study Service and Support Download Warranty After-sales Service Monitoring PV Plant Design FAQ Enterprise Explore Newsroom Video Center Event Registration About US Company Profile SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering system owners with all the data they need. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. My data logger appears to be working fine but I also notice it now glows red, appears to be a red LED inside the logger. If the connection is weak (1-2 bars) then it is recommended to install aWiFirange extender to boost the signal strength where the logger is going to be. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:-Reorient or relocate the receiving antenna.-Increase the separation between the equipment and receiver.-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.-Consult the dealer or an experienced radio/TV technician for help. Once you've connected to the "AP" network, return to, and then look for the home network that you wish to connect the logger to. When there is a problem with any of the Solis inverters, plant operation and maintenance (O&M) professionals will appreciate that the GinlongPro APP will connect to the inverter's data logger. We use cookies to try and give you a better experience in Freshdesk. 2023 AGL recognises the Aboriginal and Torres Strait Islander peoples as the Traditional Owners of the lands on which we work, and we acknowledge those communities' continuing connections to their lands, waters and Solis Data Logging Stick GPRS/WiFi Installation Video Solis 46.7K subscribers 15K views 9 months ago Solis monitoring system is centred around the photovoltaic power station, focusing on. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This device complies with part 15 of the FCC Rules. This new monitoring platform will empower you like never before. After the configuration is completed, click and back to the main page. 2. Go to your WIFI Connections 2. Let us know how can we improve this article! If you hate cookies, or are just on a diet, you can disable them altogether too. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . Copyright@2020 Ginlong Technologies All rights reserved, Data Logger is fairly similar to the Cellular Data Logger's process. 1. Go to your web browser - Input 10.10.100.254 4. Solis Monitoring. Wi-Fi communication range: 300m in outdoor open area without obstruction. Dataloggers can be scanned or added manually by entering in the serial number. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis Data Logger Server Information - wyjtki w firewall'u, Pylon US2000C/US3000C Battery - CAN Failure - No Battery - Deutsch, Solis Data Logger Server Information - firewall exceptions. solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right solis S4-GPRS GPRS Stick Datalogger Installation Guide, solis SOL-DLS-W Data Logger Wifi Stick User Guide, DAIKIN BRP069B45 WiFi Adapter Installation Guide, ideal lux 306445 Clara PL Square 4000K Ceiling Light Owners Manual, Microderm GLO NVD-MGM-GR1802 Blackhead Remover Pore Vacuum User Guide, AVALON A3F Bottom Loading Water Cooler Water Dispenser User Manual, boAt Wave Lynk Voice Premium Smartwatch User Manual, motorline RAP50 Microwave Presence Sensor User Manual, kbice FDFM1JA01 Self Dispensing Nugget Ice Machine User Guide, LUMINAR EVERYDAY 59250 2ft LED Linkable Plant Grow Light Owners Manual, Viatom Blood Pressure Monitor BP2 & BP2A User Manual. The warranty shall be executed by the terms included here but not limited to PO/Pl/Cl of goods. Thanks Peter. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. Otherwise, the communication quality may be affected. Enter the password for the network and then tap "Next". Step 3: Confirm the plant information.Click Create a plant.Step 4: Click View plant to enter the plant homepage, then add the datalogger. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. Please provide the following information as well: Ginlong Technologies Co., Ltd.No. I had to go up to the attic and actually point the antenna towards my router. Interaction, Climate Change, Sustainability & Verify the RSSI (signal strength) is higher than 15%. We use cookies to try and give you a better experience in Freshdesk. 5. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Never lost connection since, so yeah you're probably having WiFi range issue. Solis Data Loggers. This is the same data as can be sent to the ginlogmonitoring.com website for centralised data collection. signal at the inverter for there to be a stable connection. Solis inverter - Ginlong data logger Solar, Batteries & Technology Questions and discussion about solar, batteries, and other renewable energy technology Solis inverter - Ginlong data logger Comet 08-05-2018 09:43 PM 6 Replies 1 Like 45040 Views Hi We have just had a solar system installed. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. 2.4 GHz. Shows the power supply status of the datalogger. ContactPlease contact us if you have any technical problems in terms of the product. Please follow the instructions below: Step3: Use your mobile phone to send a text message to the SIM card in the stick. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. You can select the corresponding server information according to the model of data logger used by the plant. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals), 4. You will need to have the, Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. I need a better guide to enable me to connect via an Apple Mac and PC. Category: Monitoring and Communication Shows the connection status between the datalogger and the server. network that uses symbols in the password. Note: the logger is unable to connect to any. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stickadmin page. Just note that the Freshdesk service is pretty big on some cookies (we love the choco-chip ones), and some portions of Freshdesk may not work properly if you disable cookies. The delay in putting it in place was due to a bug/update issue. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Yes 2. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. If it does not reconnect than with your laptop/phone search for new open access point and try to connect to wifi stick, maybe it has lost settings. Select Network, fill in the IP address assigned by the router/network administrator LAN Stick - DLS-L 1: Connect LAN stick to operational inverter to provide power to LAN stick. How do you connect Solis? If the WIFI stick doesn't show a connected inverter check the address of the inverter. When configured correctly (see below), Solis invertors will send data about their performance every 5 minutes to code waiting to receive the data. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Connect your laptop to the Solis Wi-Fi network - this has a name which looks like "AP-xxxxxxxxx" 3. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . Did you get a response from Ginlong? Did you find it helpful? S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. If the plant has multiple data loggers, please click View Plant. *, We appreciate your effort and will try to fix the article. Enter the password for the network and then tap "Next". logger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. 2. Screenshot of the Status page in the configuration interface. If you hate cookies, or are just on a diet, you can disable them altogether too. Plug the logger into the inverter - be sure the inverter is on with at least DC power, Open the Wi-Fi settings on your phone and then search for new networks, Look for a network called "Solis_XXXXXXXXXX" the "XXXXXXXX" should be the serial number of the logger, Open a browser on your phone and enter 10.10.100.254 into the address bar, Enter "admin" for the password and "123456789" for the password then hit Log In, Go to Quick Set and then tap Search in the top left corner, Select the local Wi-Fi network that you wish to use, Enter the Wi-Fi network password (be sure that it is correct) and then tap Save, If everything was done correctly, the "Solis_XXXXX" network should disappear and the NET/COM lights on the logger should begin flashing, At this point you can go to SolisCloud and add the data logger to your plant, Use the scanner to scan the QR code sticker on the logger, Place your hand behind the logger if the scanner is not working (this helps it to focus), If you are still not having luck scanning the logger you can enter the serial number manually, Go to the Device tab on your plant and then to the Data Logger tab, The data logger should now be displayed here with note about when it last reported. Monitoring Accessory Configured But Still Won't Link? RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. If you have not already been registered onSolisCloud, please see Step 18:SolisCloudMonitoring Platform. I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed; Reset WiFi Stick to Factory Settings If it is set to one verify the WIFI stick has a good connection to the inverter. Open the Local Connection Status, click. Open the SolisCloud app on your phone. Victor is the author of this solution article. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. I will ask AGL for a replacement. Hi all, The AutoSave Draft feature is now disabled across the site. Solis Inverter Data Logger Issue. Michael is the author of this solution article. You can select the corresponding server information according to the model of data logger used by the plant. Questions and discussion about solar, batteries, and other renewable energy technology. Ginlong Solis solar inverters Preamble. If you hate cookies, or are just on a diet, you can disable them altogether too. See if this helps you out https://www.youtube.com/watch?v=0F0aGeTOYw8. I've been in contact with the team at . Is there a trick to setting it up properly that I am missing? Almost all of their products have an Modbus RS-485 interface for reading live status and statistics.. ESP8266 Solis to InfluxDB logger. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. Connect one end of an ethernet cable to LAN stickand other end directly to a computer. on Properties, select internet protocol IPv4(TCP/IPv4). Solis WiFi Data Logger Installation Guide, Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the displayed list of plants, Tap on the plant, then tap "Device" towards the top just to the right of "Overview", Tap "Datalogger" and then left-swipe the logger with your finger - you will see "Delete" in red to the right of the device, Tap "Delete" and then tap "Delete" again when asked if you want to disassociate the datalogger, "Deleted successfully" should appear - swipe down on the page to refresh it - the deleted datalogger should disappear from the device list as shown below, The deleted datalogger can now be installed on a different site/inverter, if that was the intention, A new datalogger can be installed at this site/on this inverter now that the old one has been removed. Router password is incorrect 3. To connect to the WIFI stick go to the WIFI connections and select the AP_XXXXXXX and connect.